NO. Test Item Unit Standard & Requirement
1 Appearance / No crack, No scar, good conformability
2 Ferrule polished end / No scar, No spot
3 Insertion loss dB SM≤ 0.3
4 Return loss dB PC≥ 50
5 Radius of curvature nm 10 ≤ R ≥ 25
6 Curvature eccentricity um < 50
7 Fiber core undercut nm < 50
8 Fall apart test dB H=1M, connector free-falling 5 times
Insertion loss change< 0.1, Return loss change< 5, No flab, No distortion
9 Repetitiveness dB Insertion loss change< 0.1. Return loss change< 5
10 Insert & pull out / Max: 2KG
11 Tensile strength dB 0- 10KG per minutes
Insertion loss change< 0.1, Return loss change< 5, No flab, No distortion
12 Anti-contortion dB 2.5Kg, 200times, 10times/minutes, +(-)80
Insertion loss change < 0.1, Return loss change< 5, No flab, No distortion
13 Package / Clean, Correctitude, No dirt; C